Feature
Automatic UPS switching10 second 200% surge power backup overload capability
Supports 1ph and 3ph flexible connection with max 36kW in parallel
Up to 135A max charge/discharge current
6 customizable charge/discharge time settings
Compatible with lead-acid and lithium batteries, with multiple battery protection features
Supports peak shaving control in both “self-use” and “generator” mode
Generator connectivity with multiple input methods and automatic generator On/Of control

Input DC (PV side)
Recommended max. PV power: 8 kW
Max. input voltage: 600 V
Rated voltage: 330 V
Start-up voltage: 90 V
MPPT voltage range: 90-520 V
Max. input current: 16 A / 16 A
Max. short circuit current: 24 A / 24 A
MPPT number/Max. input strings number: 2/2

Battery
Battery type: Li-ion / Lead-acid
Battery voltage range: 40-60 V
Max. charge / discharge power: 5 kW
Max. charge / discharge current: 112 A
Communication: CAN/RS485

Output AC (Grid side)
Rated output power: 5 kW
Max. apparent output power: 5.5 kVA
Operation phase: 1/N/PE
Rated grid voltage: 220 V / 230 V
Rated grid frequency: 50 Hz / 60 Hz
Rated grid output current: 22.7 A / 21.7 A
Max. output current: 25 A
Power factor: >0.99 (0.8 leading – 0.8 lagging)
THDi: <2%

Input AC (Grid side)
Input voltage range: 187-253 V
Max. input current: 32 A
Frequency range: 45-55 Hz / 55-65 Hz

Output AC (Back-up)
Rated output power: 5 kW
Max. apparent output power: 2 times of rated power, 10 s
Back-up switch time: <4 ms
Rated output voltage: 1/N/PE, 220 V / 230 V
Rated frequency: 50 Hz / 60 Hz
Rated output current: 22.7 A / 21.7
Max. output current: 32 A
Max. AC Passthrough current: 40 A
THDv (@linear load): <2%

Efficiency
Max. efficiency: > 97.5%
EU efficiency: > 96.2%

Protection
DC reverse-polarity protection: Yes
Ground fault monitoring: Yes
Integrated AFCI (DC arc-fault circuit protection): Yes
Protection class/Over voltage category: I/II

General Data
Dimensions (W*H*D): 406*560*205 mm
Weight 24 kg
Topology: High frequency isolation (for battery)
Operating ambient temperature range: -40 ~ +60°C
Ingress protection: IP66
Cooling concept:Natural convection
Max. operation altitude: 4000 m
Grid connection standard: NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA
Safety/EMC standard: IEC/EN 62109-1/-2, EN 61000-6-2/-3

Features
DC connection: MC4 plug (PV port) / Terminal Block (BAT port)
AC connection: Terminal Block
Display: LED + APP
Communication: RS485, CAN, Optional: Wi-Fi, GPRS, LAN